Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector

Product Details
Customization: Available
Type: Electrochemical Gas Sensor
Conductivity Type: Non-conductivity Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
  • Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
  • Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
  • Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
4H2S-100
Output Signal Type
Analog Type
Production Process
Integration
Material
Metal
Sensitivity
High
Certification
CE
Customized
Non-Customized
Temperature
-40ºC ~ +50ºC
Use
Air Quality Sensor
Pressure Factor
< 0.02% Signal /Mbar
Mounting Type
3 Pin
Pressure
Atmospheric Pressure ±10%
Repeatability
1% Output Signal
Linearity
Linearity, Regression Coefficient R2=0.999
Humidity
15%~90%Rh
Lifetime
2 Years (in Air)
Warranty
1 Year (From The Date of Shipment)
Output Current Polarity
Positive Current
Transport Package
Cartons
Trademark
Maiya Sensor Tech
Origin
Ningxia, China
HS Code
9027100090
Production Capacity
5000PCS/Year

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
Product Description

Sure! Here's a detailed product description for the H2S-100 Hydrogen Sulfide Gas Sensor:

 

Product Description:

The H2S-100 Hydrogen Sulfide Gas Sensor is an advanced electrochemical sensor designed for the accurate detection of hydrogen sulfide (H2S) gas. This sensor is ideal for a wide range of industrial applications, including leak detection in chemical plants, wastewater treatment facilities, and underground pipeline galleries. The H2S-100 sensor employs a constant potential electrochemical detection principle, which ensures high precision and reliable performance even in challenging environments.

The sensor generates a current proportional to the concentration of hydrogen sulfide detected in the air. This output is linear, providing a consistent response across the sensor's measurement range of 0-100 ppm, making it a powerful tool for monitoring hazardous gas levels. The H2S-100 features a fast response time (T90 < 30s), ensuring quick detection of gas concentrations, which is critical for maintaining safety in high-risk environments.

With a resolution of less than 0.5 ppm and an ultimate overload output of 500 ppm, the sensor offers high sensitivity and precise measurements. It operates effectively in a wide range of temperatures from -40°C to +50°C and can function in humid environments (15%-95% RH) without condensation, making it suitable for diverse industrial conditions. The sensor's expected service life is up to 24 months in air, with long-term output drift of less than 2% signal value per month.

The H2S-100 sensor is designed with enhanced durability, featuring a leak-proof structure that protects the sensor from external contaminants. The sensor also offers anti-interference capabilities, minimizing false readings caused by other gases such as carbon monoxide, hydrogen, ammonia, ethanol, and carbon dioxide. This makes it particularly suitable for environments with a variety of potential interfering substances.

To ensure longevity and reliable performance, the sensor should be installed in a suitable environment, avoiding prolonged exposure to volatile organic compounds, high concentrations of solvent vapors, or extreme acid/alkali conditions. The recommended storage temperature is between 0°C and 20°C, and the sensor should be used within six months of unboxing to maintain optimal function.

In addition to its robust performance, the H2S-100 sensor is easy to integrate into existing gas detection systems and can be installed using welded leads. Its compact design and straightforward installation process make it an excellent choice for industries where space and ease of deployment are critical considerations.

Key Features:

  • High sensitivity and precision for H2S detection
  • Linear output and fast response time (T90 < 30s)
  • Operating temperature range: -40°C to +50°C
  • Humidity tolerance: 15%-95% RH (no condensation)
  • Long-term stability with minimal drift (<2% signal value/month)
  • Cross-interference immunity from common gases like CO, H2, NH3, and ethanol
  • Leak-proof structure for enhanced durability and safety
  • Ideal for industrial leak detection and environmental monitoring

The H2S-100 Hydrogen Sulfide Gas Sensor provides reliable, real-time gas detection, helping protect workers and facilities from the risks associated with hydrogen sulfide exposure.

Here's a table in English that presents the technical specifications for the H2S-100 Hydrogen Sulfide Gas Sensor:

Parameter Specification
Measuring Gas Hydrogen Sulfide (H2S)
Measuring Range 0 - 100 ppm
Ultimate Overload 500 ppm
Output Signal 0.4 ± 0.15 μA/ppm
Resolution < 0.5 ppm
Response Time (T90) < 30 seconds
Zero Drift < 1 ppm
Output Linearity Straight Line (Linear Output)
Operating Temperature -40°C to +50°C
Operating Humidity 15% - 95% RH (no condensation)
Operating Pressure Range 1 ± 0.1 atm (standard atmospheric pressure)
Long-Term Output Drift < 2% signal value/month
Recommended Storage Environment In a closed container, 0°C - 20°C
Expected Service Life 24 months in air
Storage Life (Original Packaging) 6 months
Warranty Period 12 months
Cross-Interference (Typical at 25°C) CO (100 ppm) < 0.5 ppm, H2 (1000 ppm) < 20 ppm, NH3(25 ppm) < 0.3 ppm, CO2 (5000 ppm) = 0 ppm, Ethanol (100 ppm) < 1 ppm
Temperature Characteristics Sensor output varies with temperature (see datasheet for specific graph)
Installation Welded lead (do not solder contact directly to sensor)
Power-on Aging Time Minimum 30 minutes after powering on
Precautions Avoid exposure to organic solvents, high concentration vapors, acid/alkali environments, and excessive impact/vibration

Let me know if you need more details or additional parameters!

Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
 
 
Company Profile
Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas DetectorReliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
 
 
 
 
Packaging & Shipping
 
Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector
FAQ
Reliable Industrial Electrochemical Hydrogen Sulfide H2s Sensor 0-100ppm for Gas Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now