Air Quality Monitoring Detector Intensity Detection

Product Details
Customization: Available
After-sales Service: Online Service
Warranty: 1 Years
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Air Quality Monitoring Detector Intensity Detection
  • Air Quality Monitoring Detector Intensity Detection
  • Air Quality Monitoring Detector Intensity Detection
  • Air Quality Monitoring Detector Intensity Detection
  • Air Quality Monitoring Detector Intensity Detection
  • Air Quality Monitoring Detector Intensity Detection
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Information
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
MYHB-NCR-D01
Customized
Customized
Portable
Non Portable
Certification
CE
Gas
O₃
Type
Electrochemical Gas Analyzer
Radiographic Testing
X-ray, Beta-Ray, Gamma-Ray
Size
400*200*550mm
Energy Range
15kev~20.0mev
Temperature
-20ºC~+60ºC
Power Supply
220V 50Hz
Customized Support
OEM, ODM
Transport Package
Cartons
Specification
400*200*550mm
Trademark
MY Sensor
Origin
Ningxia, China
HS Code
902710090
Production Capacity
100000

Product Description

Air Quality Monitoring Detector Intensity Detection
Product Description

 

The detector is mainly for real-time online monitoring of X, gamma and neutron rays in radioactive sites, and can be composed of a monitoring controller and multiple detectors. The monitor can communicate with the detector through RS485 bus, and can also monitor the data with some detectors through 4G network to display the dose rate of each detector in real time. At the same time, the monitoring data can be uploaded to the server for remote monitoring.

Air Quality Monitoring Detector Intensity Detection

The product has following characteristics:

Alarm threshold can be set, with acoustic and optical alarm functions.

♦ 24H real-time monitoring.

Through 4G/WiFi network connection service management system, the detector data can be uploaded to achieve remote monitoring.
♦ Historical data stored and shared to cloud service system platforms, and can be export.

Air Quality Monitoring Detector Intensity DetectionAir Quality Monitoring Detector Intensity Detection


Product Parameters
Table 2-1 Parameter Table for each monitored gas
 
Work voltage DC5V ±1%/DC24V ±1% Potter rate 9600
Response time <30S Detection principle Electrochemistry
NO2 measurement range / resolution 0-20/0.001ppm SO2 measurement range / resolution 0-20/0.001ppm
CO measurement range / resolution 0-100/0.001ppm O3 measurement range / resolution 0-5/0.001ppm
PM1 measurement range / resolution 0-20m g/m3
0.01ug/m3
TSP measurement range / resolution 0-20m g/m3
0.01ug/m3
Vocs measurement range / resolution 0-20/0.001ppm Digital signal format Support for 232 / 485 transmission format, 4G transmission
Sampling accuracy ±2%FS Work humidity 10~95%RH(non-condensation)
Repeatability ±1%FS Long-term drift ≤ 1%FS/ years
Work temperature -20-70ºC Preheat time 30S
Storage temperature -40-70ºC Workpressure 86kpa ~106kpa
Work current ≤50mA Quality warranty period One year
Service life Two years Case material Aluminum alloy

Table 2-2 Parameter parameter
Execute standards ISO14644-1(FS209E)AQ/T4268-2015
Technical principles Light scattering
Grain diameter channel PM1/PM2.5/PM10/TSP Power supply 12V-24V
Recreability ≤±2% Flow speed 1L/min± 5% constant flow
Measurement accuracy ≤±10% Communication mode RS485/RS232
Resolution 0.01μg Communication protocols Modbus RTU[slave station]
Maximum valid range 20mg/m3 Interface 5 Core Air Plug
Outdoor protection level IP65 Protection Have the sensor sheath gas protection
Detection cycle Default 60s (1-999s adjustable, recommended ≥ 6s)
Use the environment Temperature: -10ºC~50ºC; humidity: < 85%RH; atmospheric pressure: 86~106kpa
Explosion level No (optional explosive isolation protection box EXDIIBT4)
Battery Optional 5200mah built-in lithium battery
System extensibility Temperature, humidity, combustible gas, oxygen, carbon dioxide, etc

Table 2-3 Parameter Table of MeteorSensor
Name Specifications and parameters
Weather sensor Wind sensor Equipment power supply: 10~30V DC
Equipment power consumption: 360°:0.2W
Working environment: -20ºC~+ 60ºC, 0%RH~80%RH
Measurement range: 0-360 ° measurement
Measuring accuracy: ± 1 °
Communication parameters: Default device address 1, Baud rate 4800
Output signal: RS485
Wind speed sensor Equipment power supply: 10~30V DC
Power consumption of the equipment: 0.1W
Wind speed accuracy: ± (0.2+0.3V) m/s V indicates the wind speed
Range of measurement: 0~60m/s
Resolution: 0.1m/s
Start-up wind speed: ≤ 0.2m/s
Response time: ≤ 0.5s
Communication parameters: Default device address 1, Baud rate 4800
Output signal: RS485
Temperature and humidity sensor Temperature range: -40ºC~80ºC
Humidity range: 0%~100%RH
Temperature accuracy: ± 0.5ºC (25ºC)
Humidity accuracy: ± 3%RH (5%RH~95RH,25ºC)
Power supply: 10~30V DC
PM2.5/PM10 range: 0 ~ 1,000 ug/m³
Operating temperature: -20~+ 60ºC, 0%RH~80RH
Output signal: RS485
Company Information
Air Quality Monitoring Detector Intensity DetectionAir Quality Monitoring Detector Intensity Detection

 

Packaging & Shipping

Air Quality Monitoring Detector Intensity DetectionAir Quality Monitoring Detector Intensity Detection

FAQ

Air Quality Monitoring Detector Intensity Detection

 

Air Quality Monitoring Detector Intensity Detection

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now