Customization: | Available |
---|---|
Type: | Electrochemical Gas Sensor |
Conductivity Type: | Non-conductivity Type |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Specification |
Operating Principle | Amperometric, 3-electrode system |
Bias Voltage | 0 mV |
Recommended Load Resistor | 100 Ω |
Warm-Up Time | < 60 seconds |
Operating Temperature Range | -40°C to +55°C |
Operating Humidity Range | 15-95% RH (Non-condensing) |
Operating Pressure Range | 800 to 1200 hPa |
Storage Temperature Range | 0°C to 20°C |
Housing Material | PPO (Polyphenylene Oxide) |
Weight | < 0.7 g |
Part Number | 01-ES1-SO2-50-01 |
Sensitivity | 20 nA/ppm ± 10 nA/ppm |
Zero Current | ± 2nA |
Range | 0-50 ppm |
Maximum Overload | 100 ppm |
Resolution (16-bit ADC) | 0.1 ppm |
Response Time (T50) | < 20 seconds |
Response Time (T90) | < 60 seconds |
Repeatability | ±1% |
Lower Detectable Limit (LDL) | 1 ppm |
Linear Range | 0-50 ppm |
Long-Term Drift | < 1% per month |
Expected Lifetime | > 3 years in air |
Zero Drift in Clean Air | < 0.2 ppm |
Storage Life | 12 months |
Warranty | 12 months |
Cross-Sensitivity to Ammonia (NH3) | No response (50 ppm) |
Cross-Sensitivity to CO2 | No response (1000 ppm) |
Cross-Sensitivity to CO | No response (50 ppm) |
Cross-Sensitivity to Cl2 | Slight response (-1 ppm at 10 ppm) |
Cross-Sensitivity to H2 | No response (100 ppm) |
Cross-Sensitivity to HCN | Minimal response (< 5 ppm at 10 ppm) |
Cross-Sensitivity to Isopropanol | No data (1000 ppm) |
Cross-Sensitivity to NO | Slight response (-3 ppm at 25 ppm) |