Product Description
Discover the ultimate in gas detection with the MST-F100 series gas detector, blending state-of-the-art ultra-large-scale integrated circuit technology with global standard intelligent techniques. This intelligent gas detection transmitter merges digital and analog communication to deliver superior technology, outstanding performance, and unparalleled stability. Designed for seamless integration, it offers robust communication and self-diagnosis capabilities, ensuring effortless installation and maintenance. Perfectly suited for industrial safety monitoring, it excels in environments demanding high reliability. Its extensive applications span across petroleum, chemical, metallurgy, refining, transmission, gas distribution, and biochemical medicine sectors. Furthermore, it effortlessly integrates with various control alarm systems, including PLC and DCS, enabling remote detection, control, and alarm functionalities with ease.
FEATURES AND BENEFITS
• Operates with a versatile (12-30) V DC power supply
• Comes equipped with a single relay output for enhanced functionality
• Offers a 3-wire 4-20mA signal output; optional RS485 or 2-wire 4-20mA available
• Features an independent sound and light alarm active output interface
• Boasts an LCD screen with a unique large character design for clear value display
• Equipped with function buttons on the display panel for easy settings operation
• Optional infrared remote-control allows convenient long-distance operation
• Alarm thresholds are adjustable, with zeroing and span-calibration options
Detection gas |
Range |
Low-point alarm |
High-point alarm |
Resolution |
Oxygen |
0-30%VOL |
19.5 |
23.5 |
0.1%VOL |
Flammable |
0-100%LEL |
20 |
50 |
1%LEL |
Carbon monoxide |
0-1000PPM |
50 |
150 |
1PPM |
Hydrogen sulfide |
0-100PPM |
10 |
20 |
1/0.1PPM |
Ammonia |
0-100PPM |
20 |
50 |
1/0.1PPM |
Hydrogen |
0-1000PPM |
200 |
500 |
1/0.1PPM |
Chlorine |
0-20PPM |
5 |
10 |
1/0.1PPM |
Hydrogen chloride |
0-20PPM |
5 |
10 |
1/0.1PPM |
Sulfur dioxide |
0-20PPM |
5 |
10 |
1/0.1PPM |
Nitric oxide |
0-250PPM |
50 |
125 |
1/0.1PPM |
Nitrogen dioxide |
0-20PPM |
5 |
10 |
1/0.1PPM |
Ethyl alcohol(C2H5OH) |
0-100PPM/100%LEL |
/ |
/ |
0.1PPM/1%LEL |
|
*Please contact us for other customized gases. |
Power supply voltage |
DC 12V ~ 30V, 500mA, power ripple is less than 20mV |
Output error |
<1% (4 ~ 20mA part) |
Relay capacity |
DC30V 1A |
Environmental range |
(-40 ~ 70) ° C (flammable) (-20 ~ 55) ° C (adjusted according to specific business needs. To achieve this value, temperature compensation is required.) (10 ~ 95) % RH without condensation |
Atmospheric pressure |
90 ~ 110Kpa |
Dimension |
193mm × 139mm × 92mm (L × W × H) |
Housing material |
Die-cast aluminum, explosion-proof and anti-corrosion |
Weight |
≈1.5 Kg (net weight of the instrument) |
Explosion-proof mark |
Ex d IIC T6 Gb |
Optional accessories:
1. External sound and light alarm for additional alert needs
2. Sensor extension probe (1.5m) for increased reach
3. 24VDC power adapter for reliable power solutions