Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output

Product Details
Customization: Available
Type: Electrochemical Gas Sensor
Conductivity Type: Non-conductivity Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
  • Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
  • Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
TB200B-EC4-HF-10
Output Signal Type
Digital Type
Production Process
Integration
Material
Metal
IP Rating
IP65
Sensitivity
High
Certification
CE
Customized
Non-Customized
Optimum Working Humidity
50% Rh
Circuit Board Size
40 X 30 X 5.6 (mm)
Description
Hf Sensor Gas
Theory
Electrochemical
Working Pressure
ATM ± 10%
Use
Hfsensor
Working Humidity
15% - 95% Rh
Range
0-10ppm
Repeatability
2%
Operating Temperature Range
-20 to +55ºC
Operating Pressure Range
800 to 1200 Hpa
Transport Package
Cartons
Trademark
EC
Origin
Germany
HS Code
9027100090

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
Product Description

EC4-HF-10 Hydrogen Fluoride Gas Sensor

The EC4-HF-10 is a high-performance electrochemical hydrogen fluoride (HF) gas sensor designed for accurate detection of HF gas in a wide range of industrial and environmental applications. Featuring a 3-electrode amperometric technology, the sensor offers exceptional sensitivity and selectivity, making it ideal for applications in industries such as semiconductor manufacturing, power transformer failure detection, glass manufacturing, and environmental monitoring.

Key Features:

  • High Sensitivity and Selectivity: Offers precise detection of hydrogen fluoride gas even at low concentrations, with a sensitivity of -350 nA/ppm ± 100 nA/ppm.
  • Stable Zero-Point: The sensor is designed for long-term stability with minimal zero drift in clean air, ensuring consistent performance over time.
  • Wide Operating Range: Operates in temperatures from -20°C to +55°C and humidity ranges of 15-95% RH, making it suitable for a variety of environmental conditions.
  • Quick Response: Features fast response times with T50 < 40s and T90 < 80s, ensuring quick detection of hydrogen fluoride gas leaks.
  • Water-Based Electrolyte: The sensor uses a water-based electrolyte for improved accuracy and long-term performance.
  • Leakage Protection: The sensor is housed in a double-sealed PPO casing for advanced leakage protection, enhancing durability and reducing maintenance.
  • Low Power Consumption: The sensor operates at zero bias voltage and requires a recommended load resistor of just 220 Ω, making it energy-efficient.
  • Cross-Sensitivity Resistance: Shows low cross-sensitivity to other gases such as arsine (AsH3), carbon monoxide (CO), and fluorine (F2), ensuring reliable HF gas detection even in complex environments.

Applications:

  • Leakage Detection: Effective for detecting HF gas leaks in various industrial settings.
  • TLV (Threshold Limit Value) Monitoring: Ideal for monitoring hydrogen fluoride concentrations in workplace environments.
  • General Industry & Semiconductor Industry: Used for monitoring HF gas levels in semiconductor manufacturing processes and other industrial environments.
  • Environmental Monitoring: Detects HF gas in air quality and environmental conditions.
  • Power Transformer Failure: Helps detect failures or malfunctions in power transformers where HF gas may be released.

Technical Specifications:

  • Sensitivity: -350 nA/ppm ± 100 nA/ppm
  • Range: 0-10 ppm (max overload 20 ppm)
  • Resolution: < 0.1 ppm
  • Response Time (T50): < 40 seconds
  • Lower Detectable Limit (LDL): ≤ 0.4 ppm
  • Operating Temperature Range: -20°C to +55°C
  • Operating Humidity Range: 15-95% RH (non-condensing)
  • Storage Temperature: 0 to 20°C
  • Expected Lifetime: 24 months
  • Housing Material: PPO
  • Weight: < 6 g

Warranty and Support:

The EC4-HF-10 sensor is backed by a 12-month warranty. The expected lifetime is 24 months under normal operating conditions, ensuring long-term reliability.
 

Parameter Specification
Sensitivity -350 nA/ppm ± 100 nA/ppm
Zero Current ± 100 nA
Measurement Range 0-10 ppm (Max Overload: 20 ppm)
Resolution < 0.1 ppm (16-bit ADC)
Response Time (T50) < 40 seconds
Response Time (T90) < 80 seconds
Repeatability ± 2%
Lower Detectable Limit (LDL) ≤ 0.4 ppm
Linear Range 10 ppm
Operating Principle Amperometric (Electrochemical)
Bias Voltage 0 mV
Recommended Load Resistor 220 Ω
Warm-Up Time < 60 seconds
Operating Temperature Range -20°C to +55°C
Operating Humidity Range 15-95% RH (Non-condensing)
Operating Pressure Range 800 to 1200 hPa
Storage Temperature 0 to 20°C
Long-Term Drift < 1%/month
Zero Drift in Clean Air < 1 ppm
Storage Life 6 months
Expected Lifetime 24 months
Warranty 12 months
Housing Material PPO (Polyphenylene Oxide)
Weight < 6 g
Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
 
 
Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
Company Profile
 
Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal OutputHydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
Packaging & Shipping
 
Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output
FAQ
Hydrogen Fluoride Gas Module 0-10ppm Tb200b-Ec4-Hf-10-01 Uart Digital Signal Output

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now