0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor

Product Details
Customization: Available
Type: Electrochemical Gas Sensor
Conductivity Type: Non-conductivity Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 15 days
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (16)
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
  • 0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
Find Similar Products
  • Overview
  • Product Description
  • Company Information
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
ES4-HCHO-100
Output Signal Type
Analog Type
Production Process
Integration
Material
Plastic
Sensitivity
High
Certification
CE
Customized
Non-Customized
Customized Support
OEM, ODM, Obm
Range
0-100ppm
Maximum Overload
200ppm
Resolution (16bit ADC)
0.1ppm
Operating Temperature Range
-20 to +55ºC
Operating Humidity Range
15-95 %Rh. Non-Condensing
Operating Pressure Range
800 to 1200 Hpa
Operating Principle
Amperometric, 3-Electrode
Expected Lifetime
> 3 Years in Air
Storage Life
12 Months
Warranty
12 Months
Housing Material
PPO
Transport Package
Cartons
Trademark
EC
Origin
Germany
HS Code
9027100090
Production Capacity
5000PCS/Year

Packaging & Delivery

Package Size
20.00cm * 15.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor
Product Description

ES4-HCHO-100 Formaldehyde Gas Sensor

The ES4-HCHO-100 is a high-performance formaldehyde gas sensor designed to deliver accurate, reliable, and fast detection of formaldehyde (HCHO) in various environments. Using solid polymer electrochemical sensing technology, it is an ideal solution for monitoring indoor air quality, industrial safety, environmental monitoring, and ensuring compliance with safety regulations for formaldehyde exposure.
This sensor is particularly effective for applications that require precise detection in both low and high-concentration environments, providing fast response times, low power consumption, and high sensitivity.
Key Features
  • High Sensitivity: The ES4-HCHO-100 sensor delivers a sensitivity of 35 nA/ppm ± 20 nA/ppm, ensuring precise measurements even at low concentrations of formaldehyde.
  • Fast Response Time: The sensor offers a rapid response time of T50 < 20s and T90 < 120s, making it ideal for real-time monitoring.
  • Wide Measurement Range: It can measure formaldehyde concentrations in the range of 0 to 100 ppm, with a maximum overload of 200 ppm, providing flexibility for different applications.
  • Lower Detection Limit: The lower detectable limit (LDL) is ≤ 5 ppm, allowing the sensor to accurately detect even trace amounts of formaldehyde in the air.
  • Long-Term Stability: The sensor shows long-term drift of less than 1% per month, and it has an expected lifetime of over 3 years in ambient air.
  • Zero Drift in Clean Air: The sensor exhibits zero drift of less than 0.2 ppm in clean air, ensuring reliable and stable performance over time.
  • Minimal Cross-Sensitivity: The sensor shows minimal interference from other gases like CO2, NH3, CH4, and ethanol, ensuring that it provides accurate formaldehyde measurements without false readings.
Parameter Value
Part Number 01-ES4-HCHO-100-01
Housing Material PPO (Polyphenylene Oxide)
Weight < 6g
Operating Principle Amperometric, 3-electrode
Bias Voltage 0 mV
Recommended Load Resistor 100 Ω
Warm-Up Time < 60 seconds
Sensitivity 35 nA/ppm ± 20 nA/ppm
Zero Current ± 2nA
Measurement Range 0 - 100 ppm
Maximum Overload 200 ppm
Resolution (16-bit ADC) 0.1 ppm
Response Time (T50) < 20 seconds
Response Time (T90) < 120 seconds
Repeatability ± 1%
Lower Detectable Limit (LDL) ≤ 5 ppm
Linear Range 100 ppm
Operating Temperature Range -20°C to +55°C
Operating Humidity Range 15% to 95% RH (Non-condensing)
Operating Pressure Range 800 to 1200 hPa
Storage Temperature Range 0°C to 20°C
Long-Term Drift < 1% per month
Zero Drift in Clean Air < 0.2 ppm
Expected Lifetime > 3 years in air
Storage Life 12 months
Warranty 12 months
Typical Applications TLV Monitoring, Indoor Air Quality, Industrial Safety, Environmental Monitoring
Cross-Sensitivity (Example Gases) CO2, NH3, CH4, Toluene, Benzene, Ethanol, Hydrogen, SO2, NO2, etc.
Test Conditions 25°C, 50% RH, Normal atmospheric pressure






 

0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor

Company Information

0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor

Packaging & Shipping
0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor

 

FAQ

 

0-100ppm Es4-Hcho-100 Electrochemical Formaldehyde Gas Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now