The detector is mainly for real-time online monitoring of X, gamma and neutron rays in radioactive sites, and can be composed of a monitoring controller and multiple detectors. The monitor can communicate with the detector through RS485 bus, and can also monitor the data with some detectors through 4G network to display the dose rate of each detector in real time. At the same time, the monitoring data can be uploaded to the server for remote monitoring.
The product has following characteristics:
♦ Alarm threshold can be set, with acoustic and optical alarm functions.
♦ 24H real-time monitoring.
♦ Through 4G/WiFi network connection service management system, the detector data can be uploaded to achieve remote monitoring.
♦ Historical data stored and shared to cloud service system platforms, and can be export.
Table 2-1 Parameter Table for each monitored gas
Work voltage | DC5V ±1%/DC24V ±1% | Potter rate | 9600 |
Response time | <30S | Detection principle | Electrochemistry |
NO2 measurement range / resolution | 0-20/0.001ppm | SO2 measurement range / resolution | 0-20/0.001ppm |
CO measurement range / resolution | 0-100/0.001ppm | O3 measurement range / resolution | 0-5/0.001ppm |
PM1 measurement range / resolution | 0-20m g/m3 0.01ug/m3 |
TSP measurement range / resolution | 0-20m g/m3 0.01ug/m3 |
Vocs measurement range / resolution | 0-20/0.001ppm | Digital signal format | Support for 232 / 485 transmission format, 4G transmission |
Sampling accuracy | ±2%FS | Work humidity | 10~95%RH(non-condensation) |
Repeatability | ±1%FS | Long-term drift | ≤ 1%FS/ years |
Work temperature | -20-70ºC | Preheat time | 30S |
Storage temperature | -40-70ºC | Workpressure | 86kpa ~106kpa |
Work current | ≤50mA | Quality warranty period | One year |
Service life | Two years | Case material | Aluminum alloy |
Execute standards | ISO14644-1(FS209E)AQ/T4268-2015 | ||
Technical principles | Light scattering | ||
Grain diameter channel | PM1/PM2.5/PM10/TSP | Power supply | 12V-24V |
Recreability | ≤±2% | Flow speed | 1L/min± 5% constant flow |
Measurement accuracy | ≤±10% | Communication mode | RS485/RS232 |
Resolution | 0.01μg | Communication protocols | Modbus RTU[slave station] |
Maximum valid range | 20mg/m3 | Interface | 5 Core Air Plug |
Outdoor protection level | IP65 | Protection | Have the sensor sheath gas protection |
Detection cycle | Default 60s (1-999s adjustable, recommended ≥ 6s) | ||
Use the environment | Temperature: -10ºC~50ºC; humidity: < 85%RH; atmospheric pressure: 86~106kpa | ||
Explosion level | No (optional explosive isolation protection box EXDIIBT4) | ||
Battery | Optional 5200mah built-in lithium battery | ||
System extensibility | Temperature, humidity, combustible gas, oxygen, carbon dioxide, etc |
Name | Specifications and parameters | |
Weather sensor | Wind sensor | Equipment power supply: 10~30V DC Equipment power consumption: 360°:0.2W Working environment: -20ºC~+ 60ºC, 0%RH~80%RH Measurement range: 0-360 ° measurement Measuring accuracy: ± 1 ° Communication parameters: Default device address 1, Baud rate 4800 Output signal: RS485 |
Wind speed sensor | Equipment power supply: 10~30V DC Power consumption of the equipment: 0.1W Wind speed accuracy: ± (0.2+0.3V) m/s V indicates the wind speed Range of measurement: 0~60m/s Resolution: 0.1m/s Start-up wind speed: ≤ 0.2m/s Response time: ≤ 0.5s Communication parameters: Default device address 1, Baud rate 4800 Output signal: RS485 |
|
Temperature and humidity sensor | Temperature range: -40ºC~80ºC Humidity range: 0%~100%RH Temperature accuracy: ± 0.5ºC (25ºC) Humidity accuracy: ± 3%RH (5%RH~95RH,25ºC) Power supply: 10~30V DC PM2.5/PM10 range: 0 ~ 1,000 ug/m³ Operating temperature: -20~+ 60ºC, 0%RH~80RH Output signal: RS485 |